Create and review analytical spaces, zones, and schedules.
Type:
Tutorial
Length:
6 min.
Transcript
00:03
After defining analytical systems and system zones.
00:07
The next step towards performing a mechanical systems
00:10
analysis is to create an energy model.
00:13
The energy model is comprised of analytical spaces containing
00:17
the information necessary for performing the mechanical systems analysis.
00:22
In this project,
00:23
we will review the energy optimization settings and consider
00:27
the building and space settings whose values are applied.
00:31
By default to the analytical spaces,
00:34
we will create and review analytical spaces then investigate the options
00:38
for overriding analytical space properties with the use of rev spaces.
00:44
Finally, we will review the analytical space output using the system browser.
00:51
Ensure the current view is H VAC floor plans. 01 H VAC plan.
00:59
Let's start with a review of the energy settings found on
01:02
the energy optimization panel of the analyzed tab of the ribbon
01:09
ensure the mode is set to use conceptual masses
01:13
and building elements from the energy analytical model area.
01:17
This is the recommended setting and caters
01:19
for architectural models that contain only masses,
01:23
only physical building elements or a mixture of both
01:28
from the advanced options.
01:30
Set the HVAC system to the option that best describes the system to
01:34
be used for the analysis and a range of assumptions will be applied.
01:39
Select central va V
01:43
set the material thermal properties to detailed elements.
01:48
This setting will use the material
01:50
thermal properties from the actual building elements
01:56
select OK. And close both dialog boxes
02:02
from the ribbon, select the manage tab then from the mep settings, dropdown menu,
02:08
select building space type settings
02:15
from the building types, select hospital or healthcare.
02:21
A review of the associated parameters and values shows the information
02:26
that will be applied to each of the analytical spaces.
02:29
When the energy model is created,
02:34
select space time and review the list of available spaces
02:42
in the filter area type hospital.
02:45
And from the list of related spaces below choose physical therapy.
02:53
If a rev
02:54
space is added to the project model,
02:56
then the analytical space created in that location will adopt the rev
03:02
space properties rather than the default building
03:05
type properties assigned to a hospital,
03:08
providing greater flexibility to adjust property values where needed
03:14
from the project browser. Open the view 03 H VAC plan
03:21
from the analyze tab select the space command
03:27
set the upper limit to roof and the offset to zero.
03:32
Then place a space in the long narrow room across the bottom of the floor plan.
03:40
Select the space.
03:41
Then from the properties change the space type to physical therapy.
03:53
Note the updated outdoor air method and the value for air changes per hour
04:01
change the cooling set point to 72 degrees.
04:07
Then select OK to close the window.
04:13
Next we'll create the energy model
04:16
from the energy optimization panel, select create energy model.
04:21
And if the additional dialog box pops up,
04:24
read the message and then go ahead and create the energy analytical model.
04:33
Once complete a visual inspection of the analytical spaces is
04:37
advised to make sure there are no obvious issues.
04:42
If the model has gaps and disconnect it can be seen here
04:45
and then a review of the energy settings may be required.
04:51
Enter the energy settings dialog box
04:55
and review the analytical space resolution
04:59
and the analytical surface resolution.
05:05
The default values here are too high in this instance,
05:09
set the space resolution to six inches
05:13
and the surface resolution to three inches
05:17
and close the dialog box
05:22
setting,
05:22
the resolution lower will improve the quality of
05:25
the analytical spaces but will increase the processing time
05:30
to see the effects of the change. The existing energy model needs to be deleted.
05:35
And a new energy model created.
Video transcript
00:03
After defining analytical systems and system zones.
00:07
The next step towards performing a mechanical systems
00:10
analysis is to create an energy model.
00:13
The energy model is comprised of analytical spaces containing
00:17
the information necessary for performing the mechanical systems analysis.
00:22
In this project,
00:23
we will review the energy optimization settings and consider
00:27
the building and space settings whose values are applied.
00:31
By default to the analytical spaces,
00:34
we will create and review analytical spaces then investigate the options
00:38
for overriding analytical space properties with the use of rev spaces.
00:44
Finally, we will review the analytical space output using the system browser.
00:51
Ensure the current view is H VAC floor plans. 01 H VAC plan.
00:59
Let's start with a review of the energy settings found on
01:02
the energy optimization panel of the analyzed tab of the ribbon
01:09
ensure the mode is set to use conceptual masses
01:13
and building elements from the energy analytical model area.
01:17
This is the recommended setting and caters
01:19
for architectural models that contain only masses,
01:23
only physical building elements or a mixture of both
01:28
from the advanced options.
01:30
Set the HVAC system to the option that best describes the system to
01:34
be used for the analysis and a range of assumptions will be applied.
01:39
Select central va V
01:43
set the material thermal properties to detailed elements.
01:48
This setting will use the material
01:50
thermal properties from the actual building elements
01:56
select OK. And close both dialog boxes
02:02
from the ribbon, select the manage tab then from the mep settings, dropdown menu,
02:08
select building space type settings
02:15
from the building types, select hospital or healthcare.
02:21
A review of the associated parameters and values shows the information
02:26
that will be applied to each of the analytical spaces.
02:29
When the energy model is created,
02:34
select space time and review the list of available spaces
02:42
in the filter area type hospital.
02:45
And from the list of related spaces below choose physical therapy.
02:53
If a rev
02:54
space is added to the project model,
02:56
then the analytical space created in that location will adopt the rev
03:02
space properties rather than the default building
03:05
type properties assigned to a hospital,
03:08
providing greater flexibility to adjust property values where needed
03:14
from the project browser. Open the view 03 H VAC plan
03:21
from the analyze tab select the space command
03:27
set the upper limit to roof and the offset to zero.
03:32
Then place a space in the long narrow room across the bottom of the floor plan.
03:40
Select the space.
03:41
Then from the properties change the space type to physical therapy.
03:53
Note the updated outdoor air method and the value for air changes per hour
04:01
change the cooling set point to 72 degrees.
04:07
Then select OK to close the window.
04:13
Next we'll create the energy model
04:16
from the energy optimization panel, select create energy model.
04:21
And if the additional dialog box pops up,
04:24
read the message and then go ahead and create the energy analytical model.
04:33
Once complete a visual inspection of the analytical spaces is
04:37
advised to make sure there are no obvious issues.
04:42
If the model has gaps and disconnect it can be seen here
04:45
and then a review of the energy settings may be required.
04:51
Enter the energy settings dialog box
04:55
and review the analytical space resolution
04:59
and the analytical surface resolution.
05:05
The default values here are too high in this instance,
05:09
set the space resolution to six inches
05:13
and the surface resolution to three inches
05:17
and close the dialog box
05:22
setting,
05:22
the resolution lower will improve the quality of
05:25
the analytical spaces but will increase the processing time
05:30
to see the effects of the change. The existing energy model needs to be deleted.
05:35
And a new energy model created.
Industry:
Role:
How to buy
Privacy | Do not sell or share my personal information | Cookie preferences | Report noncompliance | Terms of use | Legal | © 2025 Autodesk Inc. All rights reserved
Sign in for the best experience
Save your progress
Get access to courses
Receive personalized recommendations
May we collect and use your data?
Learn more about the Third Party Services we use and our Privacy Statement.May we collect and use your data to tailor your experience?
Explore the benefits of a customized experience by managing your privacy settings for this site or visit our Privacy Statement to learn more about your options.