• InfoWorks WS Pro

Performing a generalized pipe break assessment

Perform a GMR for a pipe break assessment.


Tutorial resources

These downloadable resources will be used to complete this tutorial:

iwsp2023M16U06_GMR_Pip_Brk_Assess.wspt

Step-by-step guide

To simulate a pipe break and assess the results, first configure the GMR to break each pipe one by one. Then, run a simulation for each break.

  1. Open a network and control in the background.
  2. In the Model Group window, right-click Generalized Multi Run Group.
  3. Select New > Generalized Multi Run Config.
  4. In the New Name dialog box, set the name to “Pipe Break Assessment” for this example.
  5. Click OK.

A new Generalized Multi Run appears in the Model Group window:

The InfoWorks WS Pro interface, with the network open in the GeoPlan and a new GMR listed in the Model Group window.

  1. Double click Pipe Break Assessment to open it.
  2. Within the Generalized Multi Run Configuration dialog box, navigate to the Test Cases tab.
  3. From the Model Group, drag and drop the “Pipes” selection list into the Selection List pane.

The corner of the WS Pro interface, with the Pipe Break Assessment dialog box shown next to the Model Group window, with the Pipes selection list dropped into the Selection List pane.

  1. Expand the Object Type drop-down and select Pipe (Control).
  2. Then in the grid, scroll down and enable Break Enabled.
  3. Set the Break Start time to 8:00.
  4. Set the Break End time to 9:00.
  5. Set the Break Type to Rupture.
  6. In the Test case name field, enter a name to be used for all test cases, such as “Pipes” for this example.
  7. Enable Append object ID to test case name.
  8. Click Add.

The table populates with the Pipes test cases:

The Pipe Break Assessment dialog box, Test Cases tab, with the parameters set for this exercise, and Add clicked so that the list of test cases appears in the grid.

  1. Click the Results tab.
  2. Select Keep all TVD results and individual summaries.

In the Pipe Break Assessment dialog box, Results tab, the option “Keep all TVD results and individual summaries” is selected.

  1. Click the Analysis tab.
  2. Select Used Stored Query.
  3. From the Model Group, expand the Stored Query Group.
  4. Drag and drop the CP<20m SQL into the Stored Query pane.
  5. Set the query time to be 02/05/2022 at 9:00.
  6. Click Save.

In the Pipe Break Assessment dialog box, Analysis tab, Use stored query is enabled, the query that controls the pipe size has been dropped into the Stored Query panel, and the time and date have been set for this exercise.

  1. From the Model Group, right-click Run Group.
  2. Select New > Run.
  3. In the Schedule Hydraulic Run dialog box, name this run “Pipe Break Assessment”.
  4. Select Experimental.
  5. Ensure that the network, control, and demand diagram are assigned, if not already.
  6. Expand the Run Type drop down.
  7. Select Normal.
  8. From the Run Type group, select Generalized Multi Run.
  9. From the Generalized Multi Run Options dialog box, specify the previously created “Pipe Break Assessment” configuration by dragging it from the Model Group and dropping it into the Configuration pane.
    OR, select Browse (>>), navigate to the desired configuration file, select it, and click OK.

The corner of the WS Pro interface, showing the Model Group, with the Pipe Break Assessment GMR dropped into the pane within the GMR Options dialog box, in the foreground, and the Schedule Hydraulic Run dialog box open in the background, with the corresponding network, control, and demand diagram loaded.

  1. Click OK.
  2. Back in the Schedule Hydraulic Run dialog box, click Run.
  3. Close the Pipe Break Assessment dialog box, if it not already closed.

After a few minutes, the run displays in the Model Group window:

The Model Group window, with the Run Group and Pipe Break Assessment nodes expanded to see all the listed pipes from the GMR run results.

Note: There are a number of simulations present, as well as the summary report. The simulations are those that have met the criteria specified in the stored query.

  1. Right-click the “Control” simulation.
  2. Select Open as….
  3. In the Select Results dialog box, click Summary Report.
  4. Click OK.

A Summary Report appears that includes a summary of each test case where the maximum pressure is below 20m:

The Summary Report for the control lists in a grid view all the test cases in the run where the maximum pressure is below 20m.

  1. Close the summary report.
  2. In the Model Group, right-click one of the test case simulations.
  3. Select Open as….
  4. In the Select Results dialog box, click Summary Report.
  5. Click OK.
  6. From here, the pipe test can be opened as a summary that is specific to that simulation, or it can be opened as simulation results on the GeoPlan, for theme application and labelling.

The Generic Multi Run Summary Report dialog box for a selected pipe, which lists its average pressure, ID, max pressure, and min pressure.