Â
Completion Time:Â Â 15 Minutes
|
·        Completion of the Swapping and Updating Blocks Lesson
 |
Objective:Â Â In this exercise, you change the symbol library setting from NFPA to IEC. Then you swap a limit switch from the NFPA library with a proximity switch from the IEC library.
|
 |
1:  If the Project Manager is not displayed, on the Project tab, Project Tools panel, click Manager.
Â
|
 |
2:  If Schematic_Editing_NFPA is the active project, skip to step 6. If it is open but not active, in the Project Manager, do the following:
■Right-click Schematic_Editing_NFPA.
■Click Activate.
â– Skip to step 6.
|
 |
3:  In the Project Manager, click Open Project.
|
 |
4:  Browse to where you installed the exercise files. Select the Schematic_Editing_NFPA.wdp project.
|
 |
5:  In the Project Manager Projects list, click the expansion node next to Schematic_Editing_NFPA to expand the drawing list.
|
 |
6:  Double-click Schematic_Editing_NFPA_04.dwg to open the drawing.
|
 |
7:  Zoom in to the upper area of rungs 406-410.
Â
|
 |
8:Â Â Swap a Block:
On the Schematic tab, Edit Components panel, click Swap/Update Block.
Â
|
 |
9:  In the Swap Block dialog box, click Swap a Block - One at a Time
Â
|
 |
10:  Click Pick New Block from Icon Menu. Click OK.
|
 |
11:  In the Insert Component dialog box, click Miscellaneous Switches.
Â
|
 |
In the NFPA: Other Switch Types dialog box, click Proximity Switch NO.
Â
|
 |
13:  Click the LS407 limit switch on rung 407.
Â
|
 |
14:  Click OK to QSave the drawing, if necessary.
Â
The machine layout drawing is opened, the component information is updated, and you return to Schematic_Editing_NFPA_04.dwg.
|
|